Data centers

    Lockout tagout and permit to work software for data centers.

    See what an isolation will take down before you apply it. Manage every lockout and permit from start to sign-off.

    Use lockout tagout on its own, or with permit to work.

    ImpactView on a phone: isolating PDU-2A shows 12 racks downstream, 2 of them single-fed (A07 and A11).
    Featured capability · ImpactView

    See what goes down before you isolate.

    ImpactView maps your power chain from utility feed to rack. Pick the equipment you plan to lock out and see everything it feeds, and whether the backup path is still live.

    Lockout tagout

    Then do the lockout safely.

    Knowing what goes down protects the uptime. This protects the people doing the work.

    Every energy source listed

    Equipment fed from two sides can still be live. Each procedure lists every source and every isolation point.

    Locked and tagged in order

    Crews follow the steps on a phone, one isolation at a time.

    Verified before work starts

    Each isolation is checked and recorded. A second person confirms where you require it.

    Everyone signed on

    Each worker and contractor signs on to the lockout. It is closed only when everyone is clear.

    Where it is used

    From the first contractor on site to the hundredth maintenance window.

    Build

    Control contractor work on a live construction site.

    Issue permits for hot work, work at height, electrical and confined space work. Every contractor signs on to the permit they work under.

    Commission

    Keep commissioning on schedule.

    Commissioning runs against the clock, with many trades on site at once. Zentri makes lockout plans quick to create and simple to carry out, and gives every team the same live view of what is locked out.

    Operate

    Do planned work without an unplanned outage.

    Working out what an isolation will take down is slow and easy to get wrong. Zentri shows you before you start, so you can be sure.

    More than half of major outages cost over $100,000. One in five cost over $1 million.

    Source: Uptime Institute, Annual Outage Analysis 2026.

    Everything it covers

    Lockout tagout and permit to work for data center work.

    • Electrical lockout procedures

      A procedure for each piece of equipment: switchgear, UPS, PDUs, generators and transfer switches. Each lists its energy sources and isolation points.

    • ImpactView

      Pick the equipment you plan to isolate and see everything it feeds. Plan the work without tracing single-line diagrams by hand.

    • A and B paths

      Check the backup path is live before you take one side down, and see which racks run on one feed during the work.

    • Step-by-step lockouts

      Crews follow the steps in order on a phone and verify each isolation before the next. A second person confirms where you require it.

    • Sign-on and shift handover

      See who is signed on to every lockout. The lockout is checked again at every shift change.

    • Testing and re-energizing

      Take locks off for testing and put them back, with a record. Close the job only when everyone is clear.

    • Permits

      Electrical, hot work, confined space and work at height. Contractors and vendors sign on to the permit they work under.

    • One record

      Every action is captured with the person and the time, from construction through operations. Export it for audits.

    Built for the people who run the work.

    Commissioning

    Know what is energized and what is locked out.

    Critical facilities

    See the impact before every isolation.

    EHS

    Sign-on, verification and closeout, all recorded.

    Contractors

    The right procedure, on the job, every time.

    Portfolio teams

    One way of working across every site.

    Site-based pricing

    Priced per site.

    One price for the whole site. Every crew and contractor can sign on.

    Sites live in 4 to 6 weeks. We import your equipment list, build your power chain and train your first crews.

    Book a demo

    Your equipment list, imported

    Your power chain is built from the list you already have.

    Integrations available

    Custom integrations with your CMMS and other systems.

    Contractors included

    Contractors sign on like your own crews, at no extra cost.